Product reference
AT 1500 unit
Lamp and sleeve
Dual-pass UV
Norweco AT 1500 UV Use the model guide, UV alarm context, lamp age, quartz sleeve condition, and treatment-train records to confirm this is the right UV disinfection component before ordering.
Norweco septic part

Norweco AT 1500 UV Light

Replacement-order support for the Norweco AT 1500 UV light and disinfection component used after advanced wastewater treatment in approved Ohio spray, discharge, and NPDES treatment trains. BE Ohio helps confirm the installed UV unit, lamp and quartz sleeve context, control enclosure, alarms, sampling history, and fulfillment path before release.

BrandNorweco SKUNORWECO-AT-1500-UV-LIGHT ConditionNew replacement part
  • Order support for a verified Norweco AT 1500 UV light request, not a generic UV bulb or unrelated inline disinfection part.
  • Fitment should be checked against the approved treatment train, upstream treatment quality, lamp age, quartz sleeve condition, and UV alarm history.
  • Shipping, local pickup, job-site delivery, and installation support are confirmed before the order is released.
Current item price $750.00
Available to order
Buy With Square

$750.00 is the current item price before applicable tax, shipping, local delivery, pickup handling, or installation labor. The Merchant shipping table currently treats this AT 1500 UV item as a 25 lb shipped item in the high-end septic-parts class, and BE Ohio confirms the final fulfillment path before release.

Do not order this as a generic lamp replacement. The AT 1500 is tied to system approval, disinfection performance, control status, sleeve condition, sampling history, and upstream treatment quality.

Online Offer Details

AvailabilityAvailable to order after BE Ohio confirms fitment, fulfillment path, and current stock timing.
ConditionNew replacement septic treatment component for verified Norweco AT 1500 UV applications.
SKUNORWECO-AT-1500-UV-LIGHT
BrandNorweco
Price$750.00 before applicable tax, shipping, local delivery, pickup handling, or installation labor.
Ordering pathUse the Square checkout link for the item and contact BE Ohio through chat or the portal if fitment, shipping, pickup, delivery, or install support needs confirmed first.

AT 1500 UV Verification Before Ordering

System roleThe AT 1500 provides ultraviolet disinfection after upstream treatment where the approved Ohio treatment train requires UV before spray, discharge, or sampling.
Published flow contextThe BE Ohio AT 1500 guide summarizes Norweco-published testing context including a 500 GPD evaluation load and 0.18 to 1.50 GPM instantaneous flow range.
Not a generic bulbThe installed unit, lamp, quartz sleeve, enclosure, safety interlock, and alarm behavior need to match the system, not just a simple light size.
Electrical contextThe Norweco installation manual references a dedicated 115 VAC single-phase 15 amp circuit for the AT 1500 system.
Disinfection contextA powered lamp can still fail treatment if the sleeve is fouled or upstream effluent carries solids, turbidity, or poor treatment quality.
Fitment checkSend photos of the UV enclosure, lamp/sleeve service record, control panel, alarm status, sample report, and permit paperwork before ordering.

Shipping, Pickup, Delivery, And Returns

ShippingMerchant listings use the conservative high-end septic-parts shipping class for this 25 lb AT 1500 UV item. BE Ohio still confirms the packaged size, destination, pickup, delivery, or shipped-order rate before release. See the shipping and returns policy.
Local pickupLocal pickup can be arranged after payment, fitment confirmation, and pickup timing are confirmed.
Job-site deliveryDelivery to an Ohio job site can be arranged when the site address, access, and timing are confirmed.
ReturnsReturn review is limited by the public policy, including new, unused, uninstalled products and approved defective or shipping-damaged claims.
TaxApplicable tax is added through the checkout or invoice path used for the order.
Install laborInstallation, troubleshooting, electrical review, lamp service, sleeve service, and NPDES maintenance work are separate from the item price.

What Happens After You Start The Order

1. Photos are reviewedBE Ohio checks the UV unit, enclosure, control panel, alarm status, and treatment-train context.
2. Fitment is confirmedThe AT 1500 UV request is matched to the approved system instead of treated as a generic light order.
3. Fulfillment is setCheckout, tax, shipping, pickup, delivery, or installation support is confirmed before release.
Need the AT 1500 checked? Send photos of the UV enclosure, lamp date, quartz sleeve, control panel, alarm status, sample report, and permit paperwork before ordering.