Norweco Septic Parts Guide

Norweco Septic Parts, Maintenance, and Replacement Notes

Norweco systems can include treatment tanks, aerators, UV disinfection, pumps, filters, controls, alarms, spray equipment, drip components, and NPDES compliance items. These pages help Ohio homeowners understand what each part does before buying a replacement or ignoring an alarm.

Aerators Bio-Kinetic filters UV disinfection A20 reaeration Effluent pumps Ohio approval Maintenance records
Start with the treatment train A Norweco part can be correct for one approved system and wrong for another. Match the model, controls, permit file, and service records before replacing equipment.

Pick the part you are trying to understand

Component spec snapshot

Use this hub to get to the hard data faster. Each component page now separates manufacturer-published values from field checks that still require the installed design, local approval, and service measurements.

ComponentPublished data shownField check that still matters
206C aerator1/6 HP, 1725 RPM, 115 volt, about 4 amps, 3 CFM air deliveryConfirm approved model, current draw, air delivery, shaft, aspirator tip, and control timing.
Bio-Kinetic filterNSF Standard 46 context, three filtration zones, settling zones, flow equalization, optional chemical feedConfirm exact device, feed tubes, service cover, gasket, locking lugs, and upstream solids condition.
AT 1500 UVNSF/ANSI 385, 500 GPD evaluation, 0.18 to 1.50 GPM tested instantaneous flow, dual-pass UVConfirm lamp age, quartz sleeve condition, current alarm, upstream treatment quality, and sampling history.
A20 air pumpPost-aeration air pump, 120 volt GFCI power, pressure switch, 1.5 L/min air-flow reference in tested Ohio configurationConfirm approved NPDES train, tubing, horizontal mounting, Service Pro input, and dissolved oxygen results.
HB-105 pump115 volt, 1/2 HP, 3450 RPM, 1/16 inch solids, 1 1/4 inch discharge, 28 GPM max, 125 ft TDH maxConfirm actual system curve, pressure requirement, filter loss, float settings, and post-repair pressure test.

Why parts pages matter for homeowners

Buying by model number is not always enough
  • Ohio approvals can name a specific treatment train, control setup, failsafe, or component combination.
  • A pump can match horsepower but miss the pump curve needed for spray or drip pressure.
  • A UV lamp can be powered but still fail disinfection if the quartz sleeve is fouled or upstream effluent is dirty.
  • An aerator can fit the opening but still be wrong for the approved Singulair configuration.
  • A Bio-Kinetic device can look seated but still have the wrong flow deck, feed tubes, gasket, or clogging cause.
  • An A20 can move air but still fail the approved NPDES logic if the pressure switch, tubing, or Service Pro input is wrong.
Maintenance records protect the property
  • Keep model tags, serial numbers, service reports, alarm history, permit packets, and sampling records together.
  • Use the customer portal or chat page to send photos before a service visit.
  • Connect component repairs to septic maintenance, not just one-time parts replacement.
  • Review larger system issues when parts fail repeatedly.

How to use this cluster

1Identify the systemFind the tank label, Norweco model, control panel, alarm panel, permit record, and service tag.
2Match the part to the designCompare the installed part with the design, ODH approval path, local health district file, and service provider notes.
3Check symptoms before buyingA UV alarm, high-water alarm, odor, weak spray, or failed sample can come from more than one component.
4Document the fixKeep the invoice, model number, lamp date, pump test, aerator reading, or service notes with the property record.

Related BE Ohio pages

Need help identifying a Norweco part?

Send the model tag, alarm photo, control panel photo, permit packet, or service record. BE Ohio can help sort whether this is a simple component issue or a larger treatment-train problem.

Start with chat